How to Care for Your 3M Littmann® Stethoscope

How to care for your 3M™ Littmann Stethoscope 3M™ is the market leading stethoscope manufacturer and they are renowned for their professional quality Littmann ® Stethoscopes. If you have just treated yourself to a brand new 3M™ Littmann ­ ® stethoscope or bought your first stethoscope for Medical School, naturally you expect it to last you many years. Unfortunately at Medisave we often speak to customers who have damaged their stethoscope due to incorrect cleaning or care procedures, the most frequent damages being splitting or hard binaural tubing, discolouration and lost diaphragms and eartips. We have created this guide to assist you in practising the correct cleaning and care procedures. This should help you to keep your stethoscope in pristine condition and extend it's lifespan. To prevent cross-contamination we recommend cleaning your stethoscope between patients. Here are our top tips for a clean and pristine stethoscope. To help you remember this we have created the acronym CLEAN:
  1. Clean diaphragms with alcohol wipes (with 70% isopropyl alcohol solution, with or without CHG) or soapy water (Please note that you should remove the diaphragm before cleaning if you are using soapy water)
  2. Leave a collar between your bare neck and your stethoscope when possible
  3. Eartips can be removed for a thorough clean – push these back on firmly
  4. Alcohol solution or wipes should be used to disinfect your tubing and chestpiece
  5. Never soak your stethoscope in any liquid
Cleaning and Care for Electronic Stethoscopes (3200, 3100 and 3000 Stethoscopes) Littmann™ Stethoscope parts fit perfectly to give you the excellent acoustic performance that they are renowned for, so when it comes to fitting or removing parts it can require some pressure. Cleaning Your Chestpiece Please note – your stethoscope should be turned off before you begin cleaning the chestpiece and diaphragm. It is not necessary to remove the diaphragm for cleaning, however you can do this if required. Hold the chestpiece with the diaphragm facing you, you can then use your thumbnail to lift the diaphragm out of the rim and remove it. You can insert a swab or the edge of an alcohol wipe (this must be contain at least 70% isopropyl solution) around the rim slot where the diaphragm sits. With a new wipe you can then thoroughly clean the rest of the chest piece. Never submerge your stethoscope in liquid, as this may lead to fluid or moisture in the components of the chestpiece which can cause it to become faulty.
Removing stethoscope rim Removing the diaphragm
Cleaning your Electronic Stethoscope Chest Piece Wiping the chestpiece clean
Re-assembling Your Chestpiece When the chestpiece and diaphragm have fully dried you can then reinsert your diaphragm. To do this place the diaphragm over the chestpiece and run your thumb around the edge so your thumbnail pushes the diaphragm back into the rim slot. Make sure that the diaphragm is fully inserted into the edge slot and is fitting tightly so that it does not fall off later. This will also ensure you get optimal acoustic performance from your stethoscope. Cleaning Your Binaurals The binaural tubing can be cleaned with an alcohol wipe. This includes both PVC tubing and the metal ear tubing. You can remove the ear tips to clean your binaural thoroughly. These should ''snap'' off and can be pushed back on once the cleaning is complete. It is recommended that this is done at least weekly if the stethoscope is worn around the neck, as skin oils will damage the tubing. As with anything else, the use of a suitable polish designed for plastics, will help maintain the tubing and prevent hardening. Battery Replacement for Electronic 3200 or 3100 Stethoscopes Hold the chestpiece and then turn the battery cap about 25 degrees anti-clockwise to remove it. When you insert the new battery make sure you have the positive end ( +) towards the tubing and the negative end (-) towards the chestpiece. You can now put the battery cap back on, turning it 25 ° to secure it. There will be a marker line on the chestpiece and battery cap, make sure these are aligned.
Opening the battery cover for 3200 and 3100 electronic Stethoscopes Twist open the battery Cover
Open 3100 and 3200 battery compartment Open battery compartment
Battery insertion for the 3100 and 3200 Electronic Stethoscope Correct battery insertion
Arrows to show the battery compartment for the 3100 and 3200 stethoscopes is correctly closed. Arrows to show the battery compartment is correctly closed.
Battery Replacement for 3000 Electronic Stethoscopes Hold the chestpiece with the diaphragm facing upwards and you will find a small screw on the neck. You will require a coin or small screwdriver to remove this. You can now remove the battery cover and push out the old battery. The new battery should be inserted with the positive end (+) facing the eartips. The + should be visible if the battery has been replaced correctly. You can now replace the battery cover and screw closed, making sure this is closed tightly. Please note that if you will not be using your stethoscope for several months it recommended that you remove the battery. Cleaning & Care for Manual Stethoscopes (Classic III, Classic II, Classic II Paediatric, Infant, Select, Master Classic II, Master Cardiology Stethoscopes) Littmann™ Stethoscope parts fit perfectly to give you the excellent acoustic performance that they are renowned for, so when it comes to fitting or removing parts it can require some pressure. Cleaning Your Chestpiece Hold the chestpiece with both index fingers and thumbs over the rim. You can now roll the rim from the chestpiece. Remove the rim from the diaphragm and clean both parts in soapy water or with an alcohol wipe. The Master Cardiology stethoscope comes with a special procedures adapter, this can be cleaned by washing in warm soapy water or with an alcohol wipe.
Cleaning the Master Cardiology paediatric and infant adapter Cleaning the paediatric and infant adapter
Re-assembling Your Chestpiece Make sure all of the parts are completely dry before you re-assemble your stethoscope. To re-assemble your chestpiece coat the inside edge of the diaphragm sparingly with talcum powder. This helps the diaphragm to rotate smoothly when you are changing the frequency and reduces any noise caused by this rotation. You can tap off any access powder by flexing the diaphragm with your fingers. Hold the diaphragm with the Littmann logo facing you and then pop the rim on, starting at one edge and moving your fingers round the rim to clip the rim fully into place. If the rim is correctly positioned it should be flush against the diaphragm all the way around. To attach the rim and diaphragm to the chestpiece insert one edge of the rim (with the diaphragm) into the edge groove on the chestpiece, you can then run your thumbs slowly around the rim to push the diaphragm into place. Check the diaphragm is fully attached all the way around so that it cannot fall off and so that you get optimal acoustic performance from your stethoscope. If you need to adjust the rim you can do this by gently pulling and rolling the rim edges. This allows the diaphragm to fall into the correct position.
Re-inserting the diaphragm for a manual stethoscope Re-inserting the diaphragm
Cleaning Your Binaurals The binaural tubing can be cleaned with an alcohol wipe. This includes both PVC tubing and the metal ear tubing. You can remove the ear tips to clean your binaural thoroughly. These should ''snap'' off and can be pushed back on once the cleaning is complete.
Cleaning your Stethoscope binaural tubing Cleaning the binaural tubing
Daily Care for your Stethoscope We understand that during the day it is convenient to wear your stethoscope around your neck, however this can lead to stethoscope tubing becoming hard and splitting due the oils in our skin breaking down the plastic. All new Littmann ® stethoscopes now include 3M's next-generation tubing, designed to be more flexible, durable and resistant to skin oils. This is great news and it should help to reduce damage to your stethoscope however we do still recommend that you keep a layer of clothing between your stethoscope and bare skin on your neck to help prevent damage. To assist you with keeping your stethoscope in pristine condition Medisave offers a wide range of Premium Ballistic Cases, carefully designed to look after your precious scope. Our cases come in two sizes, Classic and Cardiology. We advise using the larger Cardiology case for Electronic or Veterinary stethoscopes as these have longer tubing and you can fit these more comfortably in the larger case as coiling the tubing very tightly to fit the smaller case can still cause damage to your stethoscope over extended periods of time.
Removing your stethoscope eartips Removing the eartips
Cleaning your Stethoscope Eartips Cleaning the eartips
Even with the best care we understand that sometimes parts get broken or go missing. At Medisave we offer a wide range of 3M™ Littmann ® spare parts, from Spare Parts Kits with rims, diaphragms and Soft-Sealing Eartips, to replacement binaural tubing. If you are unsure of the part you require or you can’t locate the part you are looking for please give Medisave Customer Service Team a call on 01305 784447 and we will be happy to help you find the right part. If you do find your Littmann Stethoscope is faulty and you think it may be under warranty you can contact the 3M™ Littmann ® Repair Centre on 0800 389 6686 and they can assist you with a repair or replacement. Medisave stethoscope cases