Nonin Avant® 2120 Tabletop Pulse Oximeter
With Noninvasive Blood Pressure
The Avant® 2120 is a compact, all-in-one portable tabletop pulse oximeter incorporating Noinvasive Blood Pressure (NIBP) monitoring for impressive versatility. The 2120 has a built-in handle for easy carrying and it can be attached to a rolling stand, enabling effortless mobility.
Nonin's pulse oximetry sensor and blood pressure cuff ranges allow the Avant® 2120 to be used on patients from paediatric to adult to adapt to every situation.
You can order Nonin pulse oximetry sensors here.
Noninvasive Blood Pressure Module
Using an oscillometric blood pressure method, the NIBP gives fast and accurate readings even if the patient is in motion. Unlike auscultatory devices, oscillometric readings are unaffected by ambient noise and conversation.
PureSAT® Pulse Oximetry
PureSAT® technology, accurately assesses the patient's blood oxygen saturation (SPO2) with pulse-by-pulse filtering, providing precise and rapid oximetry measurements. PureSAT® measurements are reliable and accurate, even in situations with patient motion, low perfusion and other conditions which usually reduce the quality of readings.
Features:
- Flexible - the Nonin Avant® 2120 gives fast, reliable results in a wide range of challenging situations
- Adjustable - the NIBP feature can be configured for either user- or system-defined dyamic inflation pressure
- Cost-Effective - because the Avant® 2120 is portable, multi-function and can be quickly reconfigured for different patients on-the-fly, fewer machines are needed
- Energy-efficient - dual-voltage adaptability or battery operation with fast recharge
- Reading History Review - up to 300 NIBP and SpO2 readings are recorded for printing and review
- Excepitional Connectivity - the Avant® 2120 can connect to nVISION® Data Management software, thermal printers and a digital to analogue converter module as required
- Pulse Strength Indicator - tricolour indicator for pulse strength
Specifications:
NIBP:
- Measurement type - Oscillometric
-
Accurate Blood Pressure Range -
- Systolic - 40mmHg to 260mmHg
- Diastolic - 25mmHg to 200mmHg
- Accuracy - ±3 mmHg
- Pulse Rate Range - < 200 BPM
- Recommended Calibration Rate - yearly OR every 10,000 reading
Pulse Oximeter:
- O2 Saturation Range - 0% to 100%
- Pulse Rate Range - 18 to 300 BPM
-
SpO2 Accuracy -
- Adults - 70% to 100% ±2 digits
- Neonates - 70% to 100% ±3 digits
-
Pulse Rate -
- No Motion - 40 to 240BPM ±3 digits
- Motion - 40 to 240BPM ±5 digits