The Cobas b 101 system is an in vitro diagnostic test system suitable for HbA1c, lipid panel, and CRP tests at the point of care, delivering quick and accurate results, and is intended for professional use in a clinical laboratory or at point of care locations, intended for near-patient testing, not for self-testing.
The Cobas b 101 system is very user-friendly, featuring a large touchscreen, full keyboard and multiple language support, so it can be used by a wide range of people, with an easy-to-follow graphical user interface to guide the user along. It also requires no calibration and is maintenance and service-free so you'll know it's always ready for when you need it.
Sample Requirements:
- Lipid disc: Direct sample application (no capillaries, tubes, or pipettes are needed), requiring only 19 μl of sample. Fresh capillary blood, K2 or K3-EDTA anticoagulated whole blood, or plasma can be used for lipids (TC, TG, HDL-TC, LDL, non-HDL).
- HbA1c disc: Direct sample application (no capillaries, tubes, or pipettes are needed), requiring only 2 μl of sample. Fresh capillary blood, K2 or K3-EDTA or lithium heparin anticoagulated venous whole blood can be used for HbA1c.
- CRP disc: Direct sample application (no capillaries, tubes, or pipettes are needed), requiring only 12 μl of sample. Fresh capillary blood or serum, K2 or K3-EDTA, or lithium heparin anticoagulated whole blood or plasma can be used for CRP.
Key Features & Specifications:
- Compliant with all relevant standards and methods (IFCC, DCCT & NGSP)
- Minimal sample requirements
- Test for multiple parameters
- Easy-to-use system with guidance from the graphical user interface
- Large touchscreen, full keyboard and multiple language support
- No calibration, maintenance and service free
- Connection to Navify POC operations
- External printer or barcode scanner allows an improved workflow and documentation
- Data download to a USB stick and then to a pc, or data download to IT solutions installed on a PC
- Direct blood sample application onto the disc from a finger prick (no capillaries, tubes, and pipettes are needed)
- Requires minimal sample volumes (2 μl for HbA1c, 19 μl for lipids, and 12 μl for CRP)
- Discs are colour-coded and clearly labelled to support correct use.
- Disc cover concept for operator safety
- Discs can be stored for more than 16 months at room temp (2-30°C)
- Single testing with HbA1c, lipid panel, and CRP, or dual testing with HbA1c and lipid panel tests
- Single test results are available in about 6 minutes (CRP less than 4 minutes) and dual testing results are available after a workflow of under 15 minutes
Contents:
- Cobas b 101 machine
- Manual
- Power adapter
- Power cable
- Optical check disc x1